The validity of the VO2 master pro for assessing VO2max and running economy in trained runners

Main Article Content

Trace A. Domny
https://orcid.org/0009-0002-2481-5936
Asha D. Phillips
Katherine L. Tibbs
https://orcid.org/0009-0007-7002-1404
Brooke M. Gilmore
Julia P. Phillips
https://orcid.org/0000-0003-2823-1145
Eric K. O'Neal
https://orcid.org/0000-0001-9732-7250
Thomas L. Andre

Abstract

Purpose: This study assessed agreement between the portable VO₂ Master Pro (VM) and a non‑portable metabolic cart (NP) for measuring VO2max and running economy (RE). Methods: Fourteen endurance‑trained runners (9 female, 5 male; age 24.7 ± 5.0 y) completed four randomized crossover trials: two VO2max tests and two RE sessions using VM or NP. RE consisted of four 5‑min bouts at 100%, 90%, 80%, and 70% of personal best 5‑km pace. Agreement was evaluated using paired t‑tests, intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and Bland–Altman analysis. Results: VM significantly overestimated relative VO2max compared with NP (65.4 ± 7.3 vs 53.5 ± 5.2 ml·kg⁻¹·min⁻¹, p< .001), with weak reliability (ICC = 0.46), high SEM (2.6 ml·kg⁻¹·min⁻¹), and unacceptable CV (14.1%). Mean bias was 11.9 ± 7.1 ml·kg⁻¹·min⁻¹. Maximal ventilation (VE) showed moderate agreement (ICC = 0.81; CV = 8.3%). Similar trends were observed across all RE intensities, with modest VO₂ agreement (ICC = 0.60–0.72) and stronger VE agreement (ICC = 0.87–0.93). Conclusion: VM substantially overestimates VO₂ and demonstrates poor agreement with NP, limiting its utility as a replacement device. Greater agreement for VE suggests oxygen sensing as a primary source of error.

Article Details

How to Cite
Domny, T. A., Phillips, A. D., Tibbs, K. L., Gilmore, B. M., Phillips, J. P., O'Neal, E. K., & Andre, T. L. (2026). The validity of the VO2 master pro for assessing VO2max and running economy in trained runners. Scientific Journal of Sport and Performance, 5(4), 598–611. https://doi.org/10.55860/MZVI6493
Section
Sport Medicine
Author Biographies

Trace A. Domny, University of Mississippi

Department of Health, Exercise Science, and Recreational Management.

Asha D. Phillips, University of Mississippi

Department of Health, Exercise Science, and Recreational Management.

Katherine L. Tibbs, University of Mississippi

Department of Health, Exercise Science, and Recreational Management.

Brooke M. Gilmore, University of Mississippi

Department of Nutrition and Hospitality Management.

Julia P. Phillips, University of Mississippi

Department of Health, Exercise Science, and Recreational Management.

Eric K. O'Neal, University of North Alabama

Cole Honors College.

Thomas L. Andre, University of Mississippi

Department of Health, Exercise Science, and Recreational Management.

References

Arampatzis, A., De Monte, G., Karamanidis, K., Morey-Klapsing, G., Stafilidis, S., & Brüggemann, G. P. (2006). Influence of the muscle-tendon unit's mechanical and morphological properties on running economy. Journal of Experimental Biology, 209(17), 3345-3357. https://doi.org/10.1242/jeb.02340 DOI: https://doi.org/10.1242/jeb.02340

Barnes, K. R., & Kilding, A. E. (2015). Running economy: Measurement, norms, and determining factors. Sports Medicine - Open, 1(1), 1-15. https://doi.org/10.1186/s40798-015-0007-y DOI: https://doi.org/10.1186/s40798-015-0007-y

Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10. PMID: 2868172. https://doi.org/10.1016/S0140-6736(86)90837-8 DOI: https://doi.org/10.1016/S0140-6736(86)90837-8

Blessinger, J., Sawyer, B., Davis, C., Irving, B. A., Weltman, A., & Gaesser, G. (2009). Reliability of the VmaxST portable metabolic measurement system. International Journal of Sports Medicine, 30(1), 22-26. https://doi.org/10.1055/s-2008-1038744 DOI: https://doi.org/10.1055/s-2008-1038744

Boileau, R. A., Bonen, A., Heyward, V. H., & Massey, B. H. (1977). Maximal aerobic capacity on the treadmill and bicycle ergometer of boys 11-14 years of age.

Brehm, M. A., Harlaar, J., & Groepenhof, H. (2004). Validation of the portable VmaxST system for oxygen-uptake measurement. Gait & posture, 20(1), 67-73. https://doi.org/10.1016/S0966-6362(03)00097-3 DOI: https://doi.org/10.1016/S0966-6362(03)00097-3

Conley, D. L., & Krahenbuhl, G. S. (1980). Running economy and distance running performance of highly trained athletes. Medicine & Science in Sports & Exercise, 12(5), 357-360. https://doi.org/10.1249/00005768-198025000-00010 DOI: https://doi.org/10.1249/00005768-198025000-00010

Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006). Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems. European journal of applied physiology, 98(2), 139-151. https://doi.org/10.1007/s00421-006-0255-0 DOI: https://doi.org/10.1007/s00421-006-0255-0

Daniels, J., & Daniels, N. (1992). Running economy of elite male and elite female runners. Medicine & Science in Sports & Exercise, 24(4), 483-489. https://doi.org/10.1249/00005768-199204000-00015 DOI: https://doi.org/10.1249/00005768-199204000-00015

Delsoglio, M., Achamrah, N., Berger, M. M., & Pichard, C. (2019). Indirect calorimetry in clinical practice. Journal of Clinical Medicine, 8(9), 1387. https://doi.org/10.3390/jcm8091387 DOI: https://doi.org/10.3390/jcm8091387

Guidetti, L., Meucci, M., Bolletta, F., Emerenziani, G. P., Gallotta, M. C., & Baldari, C. (2018). Validity, reliability and minimum detectable change of COSMED K5 portable gas exchange system in breath-by-breath mode. PLOS ONE, 13(12), e0209925. https://doi.org/10.1371/journal.pone.0209925 DOI: https://doi.org/10.1371/journal.pone.0209925

Joubert, D. P., Guerra, N. A., Jones, E. J., Knowles, E. G., & Piper, A. D. (2020). Ground contact time imbalances strongly related to impaired running economy. International Journal of Exercise Science, 13(4), 427. https://doi.org/10.70252/DBRF4451 DOI: https://doi.org/10.70252/DBRF4451

Kenney, W. L., Wilmore, J. H., & Costill, D. L. (2012). Physiology of sport and exercise (5th ed.). Human Kinetics.

Kim, J., Hong, K. R., Hwang, I. W., Wen, X., Shen, J. H., Kim, H. J., et al. (2025). The validity of the V̇O₂ Master Pro for measuring oxygen consumption during sedentary activity and treadmill walking and jogging. Applied Physiology, Nutrition, and Metabolism, 50, 1-11. https://doi.org/10.1139/apnm-2025-0095 DOI: https://doi.org/10.1139/apnm-2025-0095

Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med. 2016 Jun;15(2):155-63. doi:10.1016/j.jcm.2016.02.012. Epub 2016 Mar 31. Erratum in: J Chiropr Med. 2017 Dec;16(4):346. https://doi.org/10.1016/j.jcm.2017.10.001 DOI: https://doi.org/10.1016/j.jcm.2017.10.001

Krouwer, J. S. (2008). Why Bland-Altman plots should use X, not (Y + X)/2 when X is a reference method. Statistics in Medicine, 27(5), 778-780. https://doi.org/10.1002/sim.3086 DOI: https://doi.org/10.1002/sim.3086

Loftin, M., Sothern, M., Warren, B., & Udall, J. (2004). Comparison of VO2 peak during treadmill and cycle ergometry in severely overweight youth. Journal of sports science & medicine, 3(4), 554.

Master VO2. (2019). Validity and reliability of the VM Pro. Retrieved from [Accessed 2026, 29 June]: https://vo2master.com/validation-studies/

McLaughlin, J. E., King, G. A., Howley, E. T., Bassett Jr, D. R., & Ainsworth, B. E. (2001). Validation of the COSMED K4 b2 portable metabolic system. International journal of sports medicine, 22(04), 280-284. https://doi.org/10.1055/s-2001-13816 DOI: https://doi.org/10.1055/s-2001-13816

Meyer, T., Davison, R. C. R., & Kindermann, W. (2005). Ambulatory gas exchange measurements: Current status and future options. International Journal of Sports Medicine, 26(S1), S19-S27. https://doi.org/10.1055/s-2004-830507 DOI: https://doi.org/10.1055/s-2004-830507

Meyer, T., Georg, T., Becker, C., & Kindermann, W. (2001). Reliability of gas exchange measurements from two different spiroergometry systems. International Journal of Sports Medicine, 22(8), 593-597. https://doi.org/10.1055/s-2001-18523 DOI: https://doi.org/10.1055/s-2001-18523

Montoye, A. H., Vondrasek, J., & Hancock, J. B. (2020). Validity and reliability of the VO₂ Master Pro for oxygen consumption and ventilation assessment. International Journal of Exercise Science, 13(4), 1382. https://doi.org/10.70252/THJT1177 DOI: https://doi.org/10.70252/THJT1177

Morgan, D. W., Craib, M. W., Krahenbuhl, G. S., Woodall, K., Jordan, S., Filarski, K., et al. (1994). Daily variability in running economy among well-trained male and female distance runners. Research Quarterly for Exercise and Sport, 65(1), 72-77. https://doi.org/10.1080/02701367.1994.10762210 DOI: https://doi.org/10.1080/02701367.1994.10762210

Oehlert, G. M., Jones, E. J., Savala, P., & Joubert, D. P. (2025). Within-day reliability of submaximal running economy testing: Implications for footwear testing. Footwear Science, 17(3), 143-151. https://doi.org/10.1080/19424280.2025.2488755 DOI: https://doi.org/10.1080/19424280.2025.2488755

Overstreet, B. S., Bassett, D. R., Jr., Crouter, S. E., Rider, B. C., & Parr, B. B. (2016). Portable open-circuit spirometry systems. Journal of Sports Medicine and Physical Fitness, 57(3), 227-237. https://doi.org/10.23736/S0022-4707.16.06049-7 DOI: https://doi.org/10.23736/S0022-4707.16.06049-7

Perez-Suarez, I., Martin-Rincon, M., Gonzalez-Henriquez, J. J., Fezzardi, C., Perez-Regalado, S., Galvan-Alvarez, V., et al. (2018). Accuracy and precision of the COSMED K5 portable analyser. Frontiers in Physiology, 9, 1764. https://doi.org/10.3389/fphys.2018.01764 DOI: https://doi.org/10.3389/fphys.2018.01764

Perkins, C. D., Pivarnik, J. M., & Green, M. R. (2004). Reliability and validity of the VmaxST portable metabolic analyzer. Journal of Physical Activity and Health, 1(4), 413-422. https://doi.org/10.1123/jpah.1.4.413 DOI: https://doi.org/10.1123/jpah.1.4.413

Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P. (2010). Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method. European Journal of Applied Physiology, 109(2), 159-171. https://doi.org/10.1007/s00421-009-1326-9 DOI: https://doi.org/10.1007/s00421-009-1326-9

Ross, R., ALDuhishy, A., & González-Haro, C. (2020). Validation of the cosmed K4b2 portable metabolic system during running outdoors. The Journal of Strength & Conditioning Research, 34(1), 124-133. https://doi.org/10.1519/JSC.0000000000003050 DOI: https://doi.org/10.1519/JSC.0000000000003050

Saunders, P. U., Pyne, D. B., Telford, R. D., & Hawley, J. A. (2004). Factors affecting running economy in trained distance runners. Sports Medicine, 34, 465-485. https://doi.org/10.2165/00007256-200434070-00005 DOI: https://doi.org/10.2165/00007256-200434070-00005

Shephard, R. J. (1984). Tests of maximum oxygen intake a critical review. Sports medicine, 1(2), 99-124. https://doi.org/10.2165/00007256-198401020-00002 DOI: https://doi.org/10.2165/00007256-198401020-00002

Thiessen, J. S., Guluzade, N. A., Faricier, R., & Keir, D. A. (2025). Reassessment of the COSMED Quark CPET and VO₂ Master Pro systems for measuring pulmonary gas exchange and ventilation. Scandinavian Journal of Medicine & Science in Sports, 35(2), e70019. https://doi.org/10.1111/sms.70019 DOI: https://doi.org/10.1111/sms.70019

Toulouse, A., Joubert, D., Oden, G., & Davis, P. R. (2022). Comparison of the VO₂ Master Pro and COSMED K5 during walking, jogging, and running. Journal of Science in Sport and Exercise, 4(2), 119-127. https://doi.org/10.1007/s42978-021-00146-w DOI: https://doi.org/10.1007/s42978-021-00146-w

Van Hooren, B., Souren, T., & Bongers, B. C. (2024). Accuracy of respiratory gas variables, substrate, and energy use from 15 CPET systems during simulated and human exercise. Scandinavian Journal of Medicine & Science in Sports, 34(1), e14490. https://doi.org/10.1111/sms.14490 DOI: https://doi.org/10.1111/sms.14490

Vincent, H. K., Madsen, A., & Vincent, K. R. (2022). Role of antigravity training in rehabilitation and return to sport after running injuries. Arthroscopy, Sports Medicine, and Rehabilitation, 4(1), e141-e149. https://doi.org/10.1016/j.asmr.2021.09.031 DOI: https://doi.org/10.1016/j.asmr.2021.09.031

Ward, S. A. (2018). Open-circuit respirometry: Real-time, laboratory-based systems. European Journal of Applied Physiology, 118, 875-898. https://doi.org/10.1007/s00421-018-3860-9 DOI: https://doi.org/10.1007/s00421-018-3860-9

Weir, J. P. (2005). Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. The Journal of Strength & Conditioning Research, 19(1), 231-240. https://doi.org/10.1519/00124278-200502000-00038 DOI: https://doi.org/10.1519/00124278-200502000-00038

Williams, T. J., Krahenbuhl, G. S., & Morgan, D. W. (1991). Daily variation in running economy of moderately trained male runners. Medicine & Science in Sports & Exercise, 23(8), 944-948. https://doi.org/10.1249/00005768-199108000-00010 DOI: https://doi.org/10.1249/00005768-199108000-00010

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.